Tenants and leases
The starting point is a room outside every tenant's demise, so tenants' leases and sub-meters are not part of the assessment.
For building owners IT park
A park's connection was sanctioned for every floor at full fit-out and full occupancy, and is drawn by the tenants who actually moved in. One landlord-held room on that margin may support an installation. An assessment and your agreement determine suitability, responsibilities and payment.
For IT parks
Every floor was provisioned at a load per square foot that assumed dense desks and cooling on every one of them. Some floors are unlet, some tenants use far less than the design allowed, and the plant runs for the ones that are there. The sanctioned figure on the park's bill is the design number, and the fixed charges are on that.
An old BMS or telecom room on the podium, a utility room beside the meter room, a fitted server room on a floor that is between tenants, or a plant-room annex. It has to be landlord-held and on the landlord's panel, not inside a tenant's demise or on a tenant's sub-meter; the assessment confirms which.
Sanctioned at a design load per square foot for every floor at full fit-out and full occupancy, and drawn by the tenants who actually moved in. Unlet floors and part-occupied ones leave their share on the bill, and the plant runs for the tenants who are there. The spare is the sanctioned figure minus the twelve-month peak, read with the facilities head from the park's own bills.
The assessment confirms the supply, tie-in and cooling an installation needs, and what your room can support.
Eligibility
What decides whether a room in an IT park can be assessed for an installation, and what the assessment then checks on site.
A room inside a tenant's demise or on a tenant's sub-meter is not a starting point.
An installation runs around the clock, so its cooling has to as well.
Access through the service core keeps visits away from tenant floors.
The general guide to the initial requirements is on the owners page.
Operating considerations
The starting point is a room outside every tenant's demise, so tenants' leases and sub-meters are not part of the assessment.
If a new tenant needs load back, or the room itself is let, what happens is confirmed in your agreement.
Parks often run plant through the night. The assessment sizes the room's cooling for the installation.
Responsibilities
What Azita does, and what is confirmed in your agreement.
| Responsibility | Azita | Building owner or customer | Confirmed in your agreement |
|---|---|---|---|
| Design | Azita | ||
| Installation | Azita | ||
| Commissioning | Azita | ||
| Operation | Azita | ||
| Metering | Azita | ||
| Funding | Confirmed in your agreement | ||
| Equipment ownership | Confirmed in your agreement | ||
| Room preparation | Confirmed in your agreement | ||
| Power | Confirmed in your agreement | ||
| Cooling | Confirmed in your agreement | ||
| Connectivity | Confirmed in your agreement | ||
| Access | Confirmed in your agreement | ||
| Maintenance | Confirmed in your agreement | ||
| Removal | Confirmed in your agreement |
Azita designs, installs, commissions, operates and meters. Everything else varies by arrangement and is confirmed in your agreement, including what a building owner or customer provides.
Hosting model
The same illustration as on the owners page, opened at typical inputs for an IT park. Its assumptions sit beside the result; the assessment and your agreement establish the actual terms.
Indicative pods from your room and power inputs
3
3 × 10 kW pods, 43.2 kW at the meter of your 100 kW
Counted from your room count and available power only. Room size and cooling are context for the assessment; they do not confirm that equipment fits.
Illustrative model, not a site-specific offer or measured earnings. It applies to hosting for others; an installation for your own work needs its own proposal.
The starting point is a landlord-held room on the landlord's panel, so tenants' leases, sub-meters and fit-outs are not part of the assessment. How the installation is metered is confirmed in your agreement.
Tell us about letting plans early. How load is returned, and what happens if the room itself is let, are confirmed in your agreement.
Yes. Cooling that runs around the clock is the hardest thing for most hosts to provide. The assessment sizes the room's cooling for the installation.
That is a separate route. A tenant who wants AI work run can start from the solutions page; hosting for others stands on its own agreement.
The solutions pageProperty assessment
The form starts with “IT park” as the building type, and you can change it. A location and a short description are enough to start.
Share a few details. We’ll help assess the space and explain what an installation would involve.